MTS Metallurgical Testing Services |
|---|---|
| Download the PDF: ROUND SPIGOT & FRAMELESS GLASS FENCE LOAD & IMPACT COMPLIANCE TEST 2 (8 downloads) |
Test Report
| To | Sorrento Glass | Report No | MTS-18493 SG | ||
| 1 / 7 Hector St Osborne Park WA 6017 | Issue Date | 04/08/2014 | |||
| Order No. | G. Vile | Test Date | 20/06/2014 |
Introduction
MTS Metallurgical Testing Services was engaged to conduct load tests on a pool fence spigot to the requirements of Australian Standard
AS 1926.1 – 2012.
Details
| ID | Item/Heat No. | Dimensions/Type/Details | Finish | Overall Assessment |
|---|---|---|---|---|
| 18493/01 | Round Spigot | 40mm Round Bolted Base Duplex stainless steel spigot |
Polished | COMPLIES |
Examinations & Tests
A visit was made to the test site to verify the installation arrangements against supplied drawings and to conduct a load test.
Summary
The results of the tests reported herein COMPLIED with the requirements of the stated standard.

Colin Lorrimar
Metallurgical Testing Manager
RESULTS
Visual Examination

The 40mm round bolted base spigot

The spigot was installed in accordance with the details of this drawing, modified to suit the 100mm thick floor at the test site.
Load Test
| Test Specification | AS 1926.1 – 2012, Appendix C | Test Procedure | MTS-TP3.1 Compression Tests – Products |
| Specimen ID | Test Load (N) | Deflection Under Load (mm) | Permanent Distortion (mm) | Observations | Assessment |
|---|---|---|---|---|---|
| 188493/01 | 330 | 23.0 | 2.0 | No damage or loosening evident. | COMPLIES |

The Bolted Base Round Spigot under test load.
Requirements:No breakage or signs of fracture or loosening of any part. Maximum Permanent Distortion: 6mm.
Remark:A specially made stiffened test jig was used to simulate the effect of an in-service load applied at 1200mm above ground level.
MTS-18493 SG This document shall not be reproduced, except in full.
Copyright © 2010~2014 Dataprime Solutions Pty Ltd. All Rights Reserved. 119903838567